Monitoring Configuration
TCP & UDP ports used by various machine connection types
Please note that this list is not exhaustive. There are some types where the firewall rules will depend on where and MTConnect adapter, agent, or both is installed on your network. This is a summary of the most common ports: Machine Type Port(s) ...
Using UA Expert to diagnose an OPC/UA Connection
When connecting a new machine via OPC/UA, it can be helpful to connect via a generic OPC/UA client to browse the tags and validate basic settings like IP address, username, and password before setting those in FactoryWiz. We recommend the UaExpert ...
Fagor 8065
The information provided here is for Fagor 8065 CNC controllers. service@fagor-automation.com Contact Fagor a few days ahead of time and they will be ready for you when you are on site. If you wait until you are on site, then you have to contact ...
FactoryWizTV Setup
Configuring FactoryWizTV Setting Up FactoryWizTV This guide covers how to setup and install FactoryWizTV applications. You will need to: Create a database user account for the application to connect with. Install and configure the ODBC connection ...
User Being Signed-Out
User Configuration User Being Signed-Out If you'd like to change the time out value to prevent users from being signed out, you can modify this setting on the server in the Internet Information Services Manager. Default time out value = 20 minutes. ...
Preparing for FactoryWiz Monitoring
Preparing for FactoryWiz Monitoring FactoryWiz Installation This document is to help you understand the preparation which is required to ensure that your system deployment goes as smoothly as possible. We want to make sure that you have a good ...
Understanding OEE
OEE Understanding OEE Overall Equipment Effectiveness Metrics that go into the OEE formula Availability Performance Quality OEE OEE = Availability% x Performance% x Quality% if: Availability = 91% (0.91) Performance = 98% (0.98) Quality = 99% (0.99) ...
NAT 1:1 Routing using a TL-R605
TL-R605 NAT 1:1 Routing using a TL-R605 The purpose of using the TL-R605 router is to connect a machine or cell controller LAN to your network. These are often used on Makino machines, Mazak robot cells and other robot cells. You can download the ...
Mazak RYM DPRNT Transmitter Service
.Net Framework 2.0 is required. Mazak RYM DPRNT Transmitter Service This is a windows service that sends received DPRNT commands from the Mazak CNC to FactoryWiz. This service is installed on the Mazak's Windows based controller. Installing the DPRNT ...
FactoryWiz Monitoring Logout Timer
Monitoring Logout Timer How to change how long before FactoryWiz logs you out Remote access the FW server. Open IIS (internet information services) In the left tree, expand sites and select wwwroot2019 Select SESSION STATE In the cookie settings ...
RYM DPRNT Transmitter Service
How to send DPRNT commands to FactoryWiz This is a windows server that sends received DPRNT commands to FactoryWiz. This service is installed on a windows service. .Net Framework 2.0 is required. Installing the DPRNT Service 1. Create a folder in the ...
FactoryWizTV Application
Configuring FactoryWizTV FactoryWizTV Application Product Name: Flipper Type: Windows Application Framework: .Net 4.0 Current Version: 24.1.0.0 Purpose To rotate different applications at a set interval on a single display. This application is ideal ...
Heidenhain F-PRINT
You will need Option 18 turned on to use this functionality. Heidenhain F-PRINT In order to capture part counts from a Heidenhain CNC with ethernet, we need to print out a command from the CNC program to say is complete. A few things you need to do ...
Hurco DPRNT Set Up
How to set up Hurco DPRNT 1. From menu button on left select "run program" 2. Will be prompted for a password. Try these: a. 46268 b. 86264 c. 8626486264 3. Run command prompt 4. Create C:\RYM folder 5. Copy net dprnt files to C:\RYM folder 6. Open ...
Add machine - Siemens OPC-UA (v4.05) Monitoring Configuration
Adding Siemens OPC-UA (v4.05) for monitoring Pre checks 1. Check the machine has the required software version 4.05 [MENU SELECT] > {diagnostics} > {version}. 2. Check if the Access My Machine option is on (if it is not on then we can turn it on ...
Okuma THiNC Monitoring Configuration
Configuring Okuma THiNC How to add an Okuma Machine The Okuma thinc api and thinc startup service must be installed prior to installing FactoryWiz onto the Okuma CNC. Getting the right files We need to know the api version for each Okuma you have so ...
Configuring Mazak for Monitoring
Configuring Mazak Configuring Mazak for Monitoring In FactoryWiz Login as an Admin Navigate to CONFIGURATION > MACHINE ADD Input the name of the machine Set the machine type to Mazak Set IP address Save. Navigate to CONFIGURATION > LICENSING Increase ...
Add Machine - Kitamura Anywhere remote for FactoryWiz Monitoring
Configure Kitamura Anywhere remote for FactoryWiz Monitoring Note: This document does not apply to Junior control. In FactoryWiz Login as an Admin Navigate to CONFIGURATION > MACHINE ADD Input the name of the machine (make an EXACT note of this name) ...
FactoryWiz Monitoring License Install (Existing Customers / New License)
Installing FactoryWiz Monitoring Licenses To install / download a new license sent from the FactoryWiz office, you will need to log into FactoryWiz with your admin credentials. Login as an admin Navigate to Licensing: CONFIGURATION > Licensing To ...
Add Machine - Haas NGC Configuration for FactoryWiz
Haas NGC Configuration for FactoryWiz On the Haas CNC 1. Press Setting and move the tab to wired connection. Here you must set the machine IP and Subnet 2. Next go to SETTINGS tab and search for setting 143. Set 8000 to use TCP port 8000 for ...
Macro Variable Part Counter
How to count with macro variables When manufacturing multiple parts per cycle, it is often easier to count them using macro variables instead of the machine counter (CNC Resettable Counter). You will need to find a spare variable in the CNC to use, ...
Does my Fanuc CNC have FOCAS?
How to determine if Fanuc CNC has FOCAS Ethernet check The best way to find out if you have FOCAS on your Fanuc i Series, is to check if you have Ethernet. This walk through will show you how to find out, without looking in any cabinets. Start by ...
Determining If You Have Fanuc Focas
How to determine if you have Fanuc Focas The best way to find out if you have FOCAS on your Fanuc i Series, is to check if you have Ethernet. This walk through will show you how to find out, without looking in any cabinets. Start by pressing [SYS] ...
Add machine - Brother C00 CNC Monitoring Configuration
How to add machine - Brother C00 CNC Monitoring Configuration Applicable to the C Series. FactoryWiz Settings Login as an Admin Navigate to CONFIGURATION > MACHINE ADD Input the name of the machine Set the machine type to Brother Set the IP address, ...
Fanuc Part Count
Determining part counts for Fanuc machines Standard Machines (not looping the program) Fanuc machines will either part count on M30/M02 or a custom M code specified. To enable the machine to count on and M30/M02 parameter 6700#0(PCM) must be 0. If ...
iPad Set Up for Use With FactoryWiz
How to set up a new iPad If using a new iPad, this guide starts after the initial setup. Please ensure the iPad is connected to the correct network and has the latest iOS installed. We combine standard iOS features Restricted Access and Guided Access ...
Configuring Fanuc Focas for Monitoring
This guide is for the embedded ethernet (CD38A) not Data Server of Fast Board. Configuring Fanuc Focas for Monitoring FactoryWiz Login as an Admin Navigate to CONFIGURATION > MACHINE ADD Input the name of the machine Set the machine type to Fanuc ...
Is my Haas a Next Gen Control (NGC)
Next Gen Control - NGC The easiest way to find out if your Haas is a NGC, is to locate the network screen. Press the SETTINGS hardkey Use the arrows to navigate to NETWORK > WIRED CONNECTION If you see the exactly same screen below then you have a ...
Haas NGC DPRNT Part Name and Part Count
For information on configuring the Haas and FactoryWiz with DPRNT, please see this KB Article. Part Name The default part name captured from the Haas NGC is the O number (example O01234). To capture something more meaningful, we can use DPRNT. Make ...
Haas NGC DPRNT
HAAS DPRNT Configuration How to setup Haas NGC DPRNT to work with FactoryWiz In order to DPRNT data to FactoryWiz from a Haas NGC there are a things to set in both the CNC settings and FactoryWiz settings. Before you input any settings, you must ...
Installing an ODBC Connector for FactoryWizTV
Configuring FactoryWizTV Installing an ODBC Connector for FactoryWizTV NOTE: You will need to create a new ReadOnly user in the MySQL database before proceeding with these instructions Please follow this article to create a new ReadOnly user. ...
Create Readonly User for Large Screens
Login to FactoryWiz with the full admin account Click the Gear icon in the upper right hand corner for Configuration menu then click the Database option and then the MySQL Console tab Paste in the following and click EXECUTE: CREATE USER ...
FactoryWiz Incorrectly Shows Pallet Loader Program as the Part ID - Macro Variable Pointer
FactoryWiz will show the current active program, which could be a probe cycle that you do not want to display. To work around this, store the program number of the program you do want to display into a variable. Here we have a main program (that we ...
Heidenhain Confirming Option 18 Enabled
Heidenhain Controller – Confirming Option 18 FactoryWiz has learned that not all of the i530 controllers have the option 18 enabled from the factory. New option for ALL Heidenhain controllers – including those which have RS232 but not Ethernet (we ...
Does my Haas have MACHINE DATA COLLECTION (MDC) - Setting 143
How to verify the existence of Setting 143 Standard Generation Control On Haas Control: Press the SETTNG hard key to display the machine’s settings page Page down and look for a setting numbered 143 with the text “MACHINE DATA COLLECT” The settings ...
Monitoring & DNC Minimum Server Specifications
FactoryWiz Monitoring & DNC Minimum Specifications Monitoring & DNC Minimum Server Specifications FactoryWiz Monitoring Server The following are the minimum and recommended specifications for computers running FactoryWiz Monitoring software. Minimum ...