How to Check for MACHINE DATA COLLECTION (MDC) - Setting 143 in Haas CNC Machines

Does my Haas have MACHINE DATA COLLECTION (MDC) - Setting 143








How to verify the existence of Setting 143

Standard Generation Control


On Haas Control:

 

  • Press the SETTNG hard key to display the machine’s settings page
  • Page down and look for a setting numbered 143 with the text “MACHINE DATA COLLECT”
    • The settings are not in numerical order, but setting 143 is often on the page with the RS232 baud rate settings, or the page immediately after (depending on software version). If you don’t see setting 143, go back and scrutinize these two pages to 

double-check.

  • If you find the setting and it has ON or OFF next to it, you are good to go


  • If none of the pages have the setting 143, you must treat this as a legacy machine


  • NOTE:  If the machine has a color screen but no setting 143 there is a chance that you can ask for a software update to add this feature. You will need to speak with your Haas dealer and give them the serial number for your machine to determine if this is possible.




Next Generation Control: NCG MACHINES shipped APROX Sep 2016 through current


  • ADDEDUM FOR HAAS NGC (Next Generation Controller) 
    • If your MACHINE DATA COLLECT has ON or OFF next to it, this does not apply to you. 

You do not have the NGC controller.  See above in standard control


  • Very early versions of the Haas NGC have setting 143, however the value is fixed at 0. Try changing the text to another number, such as 8002.
  • If you cannot change the value from 0, you have a version of the software where MACHINE DATA COLLECT was not yet implemented.
    • You will need to get a software update from your local Haas dealer. If you can change the value, your machine is ready to use the machine data collect feature.




    • Related Articles

    • Troubleshooting Haas MDC (serial) Machines

      Data collection for Haas MDC is performed in the DNC module. Haas CNC setting 143 must be enabled. Troubleshooting Haas MDC (serial) Machines Open the DNC Client Login as the admin Select the machine in question. Check the activity log for connection ...
    • Haas NGC DPRNT

      HAAS DPRNT Configuration How to setup Haas NGC DPRNT to work with FactoryWiz In order to DPRNT data to FactoryWiz from a Haas NGC there are a things to set in both the CNC settings and FactoryWiz settings. Before you input any settings, you must ...
    • Add Machine - Haas NGC Configuration for FactoryWiz

      Haas NGC Configuration for FactoryWiz On the Haas CNC 1. Press Setting and move the tab to wired connection. Here you must set the machine IP and Subnet 2. Next go to SETTINGS tab and search for setting 143. Set 8000 to use TCP port 8000 for ...
    • 8.7.8 Machine Connections

      In order to obtain a license for a machine, you must identify the type of machine you are configuring in the Set Machine Type pane. The type of machine will also determine which settings you are allowed to configure. As you work through the ...
    • Troubleshooting Haas NGC Connection and DPRNT Test

      This guide assumes you have setup the CNC settings and FactoryWiz in this KB Article. Ping Test We use a ping test to see if the server can see the Haas machine with its given IP address. In this example, our Haas has an IP of 192.168.0.19. See how ...