DNC Troubleshooting
Unable to Establish a Connection with the Server (License Exceeded)
Make sure all clients are closed or set to automatically log out after so many minutes. To do this: Login to the DNC as an admin System Settings Set the signet timer to a value greater than zero. You might still need to restart the DNC Server Service ...
Brother C00 FTP Configuration
CNC Configuration Sheet for FTP – Brother C00 You will need to verify all parameters listed below that correspond to your CNC control. Document (Phone camera) original settings before making modifications! CNC Parameters: Press EDIT button. Press ...
Custom Services
Installing a Custom Service Copy the files you have received to C:\Program Files\RYM\CNC Monitoring Suite on the FactoryWiz server Make a note of the name of the exe file (it is usually RYM YOUR COMPANY NAME.exe, we'll use RYM Customer Name in this ...
Troubleshooting - PDF Email Reports not Sending
FactoryWiz monitoring uses uses a utility called CRProcess to send email reports. Sometimes this file is blocked by security and needs unblocking. Procedure: Remote Desktop into the FactoryWiz server Go to folder C:\Program Files\RYM\CNC Monitoring ...
Comtrol DeviceMaster IP Configuration Procedure
Comtrol DeviceMaster IP Configuration Procedure Download and install PortVision DX version 3.05 from the Comtrol website. (ftp://ftp.comtrol.com/html/DM_PRO_RTS_SERIALHUB_pvpx.htm) Launch msi file that was downloaded. Click Run. Click Next 3. Accept ...
FactoryWiz DNC Self-Installation Instructions
Getting started Here is a link to our download site for all of the FactoryWiz DNC downloads, Quickstart Guides and videos and common machine configurations that will help you get started with your installation: Software Download Page From the ...
Paperclip Loopback Test
This test is to confirm whether you have two-way communication on your port. How to test Open FactoryWiz DNC Select a machine Click Terminal Mode Unplug RS232 cable from the machine. At the end you just unplugged, have someone hold a paperclip to ...
Cable Diagrams and Descriptions with Pinouts
Pinout 1: No Handshake Jumper? DB-9 PC (Female) Wire DB-25 CNC (Male) Jumper? (Disconnected) Shield 1 2 (Receive Data) Green 2 (Transmit Data) 3 (Transmit Data) Red 3 (Receive Data) 5 (Signal Ground) Black 7 (Signal Ground) 4 (RTS) 5 (CTS) JUMPER 6 ...
"DR Signal Off" Alarm (Often Alarm 086 on a Fanuc)
This alarm occurs when the CNC checks the data ready handshake line (sometimes called DR or DTR) and finds that the device is not ready. There are a few possibilities for this problem depending on how your cables are wired. Verify that your port is ...