Setting screen:
Punch code- 1=ISO
TV CHECK=0 OFF
Under Service page:
0000 = xxx01000 (ISO)
0020 = 2 (Input device Foreground)
0021 = 2 (Output device Foreground)
0022 = 2 (Input device Background)
0023 = 2 (Output device Background)
5001 to 1 (Device Select)
5002 to 2 (RS232 Device Select)
5110 to 3 (Device type DC Codes used)
5111 to 1 (1 stop bit)
5112 to 10 (4800 baud) 11=9600, 9=2400, 8=1200 7=600 6=300
Basic Communication
1.01- Port Type: Standard
1.11- Baud: 4800
1.12- Data Bits: 7
1.13- ASCII Even
1.14- Stop Bits: 1
1.15- Handshake: XON/XOFF
Sending Options
2.11- Leader: %<10>
2.12- Trailer: %
2.23- Skip lines that contain: %
2.31- Automatic timeout: 7
Receiving Options
3.11- Program identifier 1: O
3.12- Program Identifier 2: :
3.21- Receive timeout: 3
3.31- Ignore data before first end-of-block: True
3.32- Ignore data after last end-of-block: True
Remote Commands
4.02- Request for file command: GET-
4.03- Request for file command (drip feed): DNC-
4:11- Request to save command: PUT-
Changing CNC Parameters:
System (Param) screen:
To set parameters, move dial to MDI mode on machine.
Press SETTINGS key. Change PWE (#8000) to 1. The CNC will alarm.
Outputting CNC Programs:
To output a program, set the CNC to "edit" mode. Press the PROG key on the control panel. Use the right arrow (Page) key until PUNCH appears. Press PUNCH, then Press THIS.
Inputting CNC Programs:
To input a program, set the CNC to "edit" mode. Press the PROG key on the control panel. Use the right arrow(Page)keys until READ appears. Press READ, then press ALL.
Pinout includes RTS/CTS Handshaking
|
DB-9 com port |
Wire color |
DB-25 CNC |
Jumper? |
|
(Disconnected) |
Shield |
1 |
|
|
2 (Receive Data) |
Green |
2 (Transmit Data) |
|
|
3 (Transmit Data) |
Red |
3 (Receive Data) |
|
|
5 (Signal Ground) |
Black |
7 (Signal Ground) |
|
|
7 (RTS) |
Brown |
5 (CTS) |
|
|
8 (CTS) |
Blue |
4 (RTS) |
|
|
|
|
6 (DSR) 8 (DCD) 20 (DTR) |
JUMPER |