Siemens 840D Serial Integration Guide

Siemens 840D Serial Configuration

CNC Parameters

You will need to verify all parameters listed below that correspond to your CNC control.  These parameters may not match your particular machine’s control.  Document (Phone camera) original settings before making modifications!

Changing CNC Parameters

Interface settings are normally found under Services.

When Services screen is shown, selections are Data In, Data Out, Manage Data, and Interface.  Choose Interface.


Select Xon/Xoff, Normal file transfer, Xon=Hex 11, Xoff=Hex13,

End of Transmission. =Hex03, Timeout: 4sec

Check the box: Send XON at Start Data on.

Check the box: Stop with EOT character.



 

FactoryWiz DNC Settings

Basic Communication

1.01- Port Type: Standard

1.11- Baud: 19200

1.12- Data Bits: 8

1.13- ASCII None

1.14- Stop Bits: 1

1.15- Handshake: XON/XOFF

1.21- End of block (EOB): LF

 

Sending Options

2.11- Leader:

2.12- Trailer: <3>

2.31- Automatic timeout: 7

 

Receiving Options

3.11- Program identifier 1: _N_  

3.12- Program Identifier 2:

3.21- Receive timeout: 3

3.31- Ignore data before first end-of-block: False

3.32- Ignore data after last end-of-block: False

 

Remote Commands

4.02- Request for file command: GET-

4.03- Request for file command (drip feed): DNC-

4:11- Request to save command: PUT-

 

 

Additional Notes

Outputting CNC Programs:

When Services screen is shown, select Data Out.

Cursor down to file you want sent.

Press V.24, then press Start.

 

Inputting CNC Programs:

When Services screen is shown, select Data In.

Cursor down to folder where you want file stored.  (If file format is correct, it will automatically be stored in the correct folder)

Press V.24, then press Start. 


 

Wiring Diagram: DB9 to DB25

Pinout includes RTS/CTS Handshaking

DB-9 com port

Wire color

DB-25 CNC

Jumper?

 

(Disconnected)

Shield

1

 

 

2 (Receive Data)

Green

2 (Transmit Data)

 

 

3 (Transmit Data)

Red

3 (Receive Data)

 

 

5 (Signal Ground)

Black

7 (Signal Ground)

 

 

7 (RTS)

Brown

5 (CTS)

 

 

8 (CTS)

Blue

4 (RTS)

 

 

 

 

6 (DSR)

8 (DCD)

20 (DTR)

JUMPER

 

Wiring Diagram: DB9 to DB9

Pinout includes RTS/CTS Handshaking

DB-9 com port

Wire color

DB-9 CNC

Jumper?

 

(Disconnected)

Shield

1

 

 

2 (Receive Data)

Green

3 (Transmit Data)

 

 

3 (Transmit Data)

Red

2 (Receive Data)

 

 

5 (Signal Ground)

Black

5 (Signal Ground)

 

 

7 (RTS)

Brown

8 (CTS)

 

 

8 (CTS)

Blue

7 (RTS)

 

 

 

 

6 (DSR)

1 (DCD)

4 (DTR)

JUMPER

 





    • Related Articles

    • Moxa Configuration Instructions-Wizard (Wireless)

      W2150A Wireless Moxa Configuration Below are a list of links to the latest drivers and firmware for the W2150A wireless Moxa units. Moxa Firmware Update NPort Windows Server 2019 and below or Windows 10 and below Driver Manager (WHQL certified) NPort ...
    • Fanuc 6MA Configuration Document

      CNC Parameters Setting (HANDY) screen: Punch code- 1=ISO TV CHECK=0 OFF Input Device 1=0 Input Device 2=1 FactoryWiz DNC Settings Basic Communication 1.01- Port Type: Standard 1.11- Baud: 4800 1.12- Data Bits: 7 1.13- ASCII Even 1.14- Stop Bits: 1 ...
    • Fanuc 6TA Configuration Document

      CNC Parameters Setting (HANDY) screen: Punch code- 1=ISO TV CHECK=0 OFF Input Device 1=0 Input Device 2=1 FactoryWiz DNC Settings Basic Communication 1.01- Port Type: Standard 1.11- Baud: 4800 1.12- Data Bits: 7 1.13- ASCII Even 1.14- Stop Bits: 1 ...
    • Fanuc 0T Configuration Document

      CNC Parameters (Phone camera) original settings before making modifications! Setting screen: Punch code- 1=ISO TV CHECK=0 OFF I/O=0 (for Channel 1) Parameters screen: 0002 = 1xxxxxx0 (do not change values for x) 0552 = 10 (4800 baud rate) 9=2400, ...
    • Fanuc 0M Configuration Document

      CNC Parameters (Phone camera) original settings before making modifications! Setting screen: Punch code- 1=ISO TV CHECK=0 OFF I/O=0 (for Channel 1) Parameters screen: 0002 = 1xxxxxx0 (do not change values for x) 0552 = 10 (4800 baud rate) 9=2400, ...