Okuma P100, P200, P300 UNC Configuration Guide

Okuma P100 P200 P300 UNC Configuration

Okuma Configuration

On the Okuma, pressing Control plus Reset (looks like /// on the key) should bring up the start menu for Windows. In the start menu you want to run, then enter "compmgmt.msc" and click ok.

 

There should be a local users and groups tab. Go to Users, right click in the user list and add a user.

Give it any name and password you like, and set the password to never expire.

 

Go back to the start menu and find the control panel. Go to network. Find the ethernet adapter, right click, go to properties. You will then need to go under tcp/ip v4 and set a fixed ip address for this machine (if not done already). Click ok, ok, close control panel.

 

Go back to the start menu, go under programs and you should see windows explorer.

Go to the D: drive. Find the MD1 folder. Right click on it, select properties.

Go to the sharing tab. Advanced sharing. Share the folder as MD1. For share permissions

check the box for "allow modify" . Click ok.

 

\\ipaddress\MD1

 

Username is set to: 

ipaddress\username

(Username that you created)

 

Password is what you entered.

 

FactoryWiz DNC Settings

In FactoryWiz Dnc, you want to set the port type to UNC under the Basic Communications column for the connection type. Not UNC intermediate - very important or the dnc could delete all of the cnc's part programs.

 

Basic Communication

1.01- Port Type: UNC

1.05- UNC path to device:  \\ipaddress\MD1   (IP Address of Okuma)

1.06- UNC return path:  \\ipaddress\MD1   (IP Address of Okuma)

1.07- UNC path Username:  Username you created at machine.

1.08- UNC path Password: Password that you created for the Username at machine.

1.21- End of block (EOB):  CRLF

 

Sending Options

2.01- Send Directories:  Where files are sent from Server to machine

2.02- Search Sub-directories: True/False - Set to True if you want Sub-directories to be allowed in seen.

2.03- Send Extensions:  Acts as filter to display only files in Send Directories.

 

Receiving Options

3.01- Receive directories: Path to where files will be placed when brought back from machine.

 


File transfer

File transfer between the Okuma and the fileserver can only be done using the FactoryWiz DNC Client.

 

Send to Okuma

Using FactoryWiz Client, select the Okuma machine, then click on Send File.

Select the Directory, then the file you would like transferred to the Okuma.

Click on Send file (Once).  (this will copy the file selected to the MD1 folder on the machine)

 

Receive from Okuma

Using FactoryWiz Client, select the Okuma machine, then click on Receive File.

The MD1 files will be listed.  Select the file for transfer.  If multiple Receive directories were configured (in 3.01), select which directory to copy the file to.

Click on Receive file.  (this will copy the file selected to the receive folder)

 

 

 

 


    • Related Articles

    • Okuma P100, P200, P300 Serial Configuration

      Okuma OSP100, OSP200, and OSP300 CNC Parameters You will need to verify all parameters listed below that correspond to your CNC control. These parameters may not match your particular machine’s control. Document (phone camera) original settings ...
    • Haas Ethernet - UNC Intermediate Local Share Configuration

      CNC Parameters You will need to verify all parameters listed below that correspond to your CNC control. These parameters may not match your particular machine’s control. Document (phone camera) original settings before making modifications! On Haas ...
    • Fanuc 6MA Configuration Document

      CNC Parameters Setting (HANDY) screen: Punch code- 1=ISO TV CHECK=0 OFF Input Device 1=0 Input Device 2=1 FactoryWiz DNC Settings Basic Communication 1.01- Port Type: Standard 1.11- Baud: 4800 1.12- Data Bits: 7 1.13- ASCII Even 1.14- Stop Bits: 1 ...
    • Fanuc 6TA Configuration Document

      CNC Parameters Setting (HANDY) screen: Punch code- 1=ISO TV CHECK=0 OFF Input Device 1=0 Input Device 2=1 FactoryWiz DNC Settings Basic Communication 1.01- Port Type: Standard 1.11- Baud: 4800 1.12- Data Bits: 7 1.13- ASCII Even 1.14- Stop Bits: 1 ...
    • Haas Configuration

      CNC Parameters Newer Haas Press SETNG to bring up the machine settings. Press right arrow until you get to I/O tab. Press WRITE/ENTER button (lower right corner of panel). Use left and right arrow to toggle between choices for each setting. Press ...