Okuma OSP100, OSP200, and OSP300
System (Param) screen:
Choose Parameters.
Page down until RS232 parameters appear for CN0.
Baud
rate: Match FactoryWiz setting.
RS232C character: 8 bit (cannot change,
but you still set to 7 data bits in FactoryWiz)
RS232C parity bit: NON
RS232C stop bit: 2
Ready waiting time: 10 sec
Flow control: DC CODE
Delay timer until RS switches OFF: 0 msec
Designates the amount of RS OFF time: 0 msec
DC2/DC4 at punch: DOES NOT
DC when read/verify finished: DOES NOT
Basic Communication
1.01- Port Type: Standard
1.11- Baud: 4800
1.12- Data Bits: 7
1.13- ASCII Even
1.14- Stop Bits: 2
1.15- Handshake: XON/XOFF
Sending Options
2.11- Leader:
2.12- Trailer: %<0>
2.27- Force upper case: True
2.31- Automatic timeout: 7
Receiving Options
3.11- Program identifier 1: $
3.12- Program Identifier 2:
3.21- Receive timeout: 3
3.31- Ignore data before first end-of-block: False
3.32- Ignore data after last end-of-block: True
3.41- Mask characters: <0><18><20>
Remote Commands
4.02- Request for file command: GET-
4.03- Request for file command (drip feed): DNC-
4:11- Request to save command: PUT-
Press Edit/Aux.
Press right screen button until RS232 appears.
Press RS232.
Press Output.
Cursor to program you want sent, press OK.
Press Edit/Aux.
Press right screen button until RS232 appears.
Press RS232.
Press Input.
Press OK. Program will load with correct name if
formatted correctly, otherwise it will load in as A.min
Pinout includes RTS/CTS Handshaking
DB-9 com port | Wire color | DB-25 CNC | Jumper? | |
| (Disconnected) | Shield | 1 |
|
| 2 (Receive Data) | Green | 2 (Transmit Data) |
|
| 3 (Transmit Data) | Red | 3 (Receive Data) |
|
| 5 (Signal Ground) | Black | 7 (Signal Ground) |
|
| 7 (RTS) | Brown | 5 (CTS) |
|
| 8 (CTS) | Blue | 4 (RTS) |
|
|
|
| 6 (DSR) 8 (DCD) 20 (DTR) | JUMPER |