Guide to FTP Configuration on Fanuc 0i

FTP - Fanuc 0i Configuration Document


CNC Parameters


Setting (HANDY) screen:

I/O=9 (for FTP)

System (Param) screen:
System button

Press >Screen button until Embedded appears.

Select Embedded

Select Common.  Enter the IP address for machine, Subnet Mask, and Router IP if necessary.

Select FTP Transfer.  Enter Host Name IP Address (of PC/Server running the FactoryWiz Server software).

Enter Port# 21

Enter Username: FTP

Enter Password: FACTORYWIZ

Page down.

Login Folder path:             (leave this field blank)


Select Restart to enable settings.


FactoryWiz DNC Settings

Basic Communication

1.01- Port Type: FTP_Server

1.03- IP Address of Fanuc control

1.21- End of block (EOB): LF


Sending Options

2.11- Leader: %<10>

2.12- Trailer: %

2.23- Skip lines that contain: %


Receiving Options

3.11- Program identifier 1: O

3.12- Program Identifier 2: :

3.21- Receive timeout: 3

3.31- Ignore data before first end-of-block: True

3.32- Ignore data after last end-of-block: True


Remote Commands

4.02- Request for file command: GET-

4.03- Request for file command (drip feed): DNC-

4:11- Request to save command: PUT-


Additional Notes

Changing CNC Parameters:


Place the NC in MDI mode
Press the SETTING function key until the "SETTING (HANDY)" page is displayed.

Cursor down to I/O Channel. Set to 9 for FTP.

Press the SYSTEM key once, then the PARAM softkey.


Description of general communication parameters:


Outputting CNC Programs:


To output a program, set the CNC to "EDIT" mode. Press the PROG key on the control panel. Display the program you wish to send on the screen by keying in the program number then pressing the down-arrow button. Press the Operate (OPRT) softkey. Use the right arrow keys (in softkey row under LCD screen) until F Output appears. Press F OUTPUT, Type in the program name, then press F SET.

Press EXEC.




Inputting CNC Programs:


Queue file to be sent at FactoryWiz Clint workstation first, then at machine control:

Set the CNC to "EDIT" mode. Press the PROG key on the control panel. Press the Operate (OPRT) softkey. Use the right arrow keys (in softkey row under LCD screen) until F INPUT appears. Press F INPUT, key in filename you would like, (a Queued file will ignore what is typed in, so you can call it anything, such as 1). Press EXEC.






    • Related Articles

    • FTP - Fanuc 0i, 30i, 31i, 32i Configuration Document

      CNC Parameters Setting (HANDY) screen: I/O=9 (for FTP) System (Param) screen: System button Press >Screen button until Embedded appears. Select Embedded Select Common. Enter the IP address for machine, Subnet Mask, and Router IP if necessary. Select ...
    • Brother C00 FTP Configuration

      CNC Configuration Sheet for FTP – Brother C00 You will need to verify all parameters listed below that correspond to your CNC control. Document (Phone camera) original settings before making modifications! CNC Parameters: Press EDIT button. Press ...
    • FTP - Fanuc 0i, 30i, 31i, 32i

      Changing CNC Parameters You will need to verify all parameters listed below that correspond to your CNC control. These parameters may not match your particular machine’s control. Document (Phone camera) original settings before making modifications! ...
    • Fanuc 0T Configuration Document

      CNC Parameters (Phone camera) original settings before making modifications! Setting screen: Punch code- 1=ISO TV CHECK=0 OFF I/O=0 (for Channel 1) Parameters screen: 0002 = 1xxxxxx0 (do not change values for x) 0552 = 10 (4800 baud rate) 9=2400, ...
    • Fanuc 0M Configuration Document

      CNC Parameters (Phone camera) original settings before making modifications! Setting screen: Punch code- 1=ISO TV CHECK=0 OFF I/O=0 (for Channel 1) Parameters screen: 0002 = 1xxxxxx0 (do not change values for x) 0552 = 10 (4800 baud rate) 9=2400, ...