Fixing Flipper Application Issues in Windows Startup

Flipper Not Working from Windows Startup Folder

For when the application will launch but does not cycle the screens.

Updating windows registry to overcome the issue

HKEY_CURRENT_USER\Control Panel\Desktop
  1. Right click on ForegroundLockTimeout > modify
  2. Change value to 0, and base to decimal.
  3. This will take effect on the next restart.



    • Related Articles

    • FactoryWizTV Application

      Configuring FactoryWizTV FactoryWizTV Application Product Name: Flipper Type: Windows Application Framework: .Net 4.0 Current Version: 24.1.0.0 Purpose To rotate different applications at a set interval on a single display. This application is ideal ...
    • Okuma THiNC Monitoring Configuration

      Configuring Okuma THiNC How to add an Okuma Machine The Okuma thinc api and thinc startup service must be installed prior to installing FactoryWiz onto the Okuma CNC. Getting the right files We need to know the api version for each Okuma you have so ...
    • Configuring Mazak for Monitoring

      Configuring Mazak Configuring Mazak for Monitoring In FactoryWiz Login as an Admin Navigate to CONFIGURATION > MACHINE ADD Input the name of the machine Set the machine type to Mazak Set IP address Save. Navigate to CONFIGURATION > LICENSING Increase ...
    • How to Restart FactoryWiz Services

      FactoryWiz talks to most machine controls (CNC / PLC) with a dedicated windows service for each control type. By that we mean all Fanuc's are controlled by one service (RYM FOCAS) and all Mazak's controlled by another service (RYM Mazak). A lot of ...
    • Heidenhain F-PRINT

      You will need Option 18 turned on to use this functionality. Heidenhain F-PRINT In order to capture part counts from a Heidenhain CNC with ethernet, we need to print out a command from the CNC program to say is complete. A few things you need to do ...