Popular Articles
"DR Signal Off" Alarm (Often Alarm 086 on a Fanuc)
This alarm occurs when the CNC checks the data ready handshake line (sometimes called DR or DTR) and finds that the device is not ready. There are a few possibilities for this problem depending on how your cables are wired. Verify that your port is ...
Fanuc Part Count
Determining part counts for Fanuc machines Standard Machines (not looping the program) Fanuc machines will either part count on M30/M02 or a custom M code specified. To enable the machine to count on and M30/M02 parameter 6700#0(PCM) must be 0. If ...
Mazak M32 Configuration Document
CNC Parameters G1 = 2 (CMT 4800 baud) G19 - 2 (EIA 4800 baud) G20 - 3 (2 stop bits) G21 - 0 (even parity) G22 - 0 (Disable parity check) G23 - 3 (8 data bits) G27 - 0 (CR/LF) G29 - 3 (XON/XOFF) G30 - 1 (No DC Code parity check) G40 - 0 (No DC2/DC4) ...
Cable Diagrams and Descriptions with Pinouts
Pinout 1: No Handshake Jumper? DB-9 PC (Female) Wire DB-25 CNC (Male) Jumper? (Disconnected) Shield 1 2 (Receive Data) Green 2 (Transmit Data) 3 (Transmit Data) Red 3 (Receive Data) 5 (Signal Ground) Black 7 (Signal Ground) 4 (RTS) 5 (CTS) JUMPER 6 ...
Fanuc 10T Configuration Document
CNC Parameters Setting screen: Punch code- 1=ISO TV CHECK=0 OFF Under Service page: 0000 = xxx01000 (ISO) 0020 = 2 (Input device Foreground) 0021 = 2 (Output device Foreground) 0022 = 2 (Input device Background) 0023 = 2 (Output device Background) ...